Rohde & Schwarz RTO2034 Digital Oscilloscope

| Attribute | Value |
|---|---|
| Bandwidth | 350 MHz |
| Number of Channels | 4 |
| Sample Rate | 5 Gsample/s (single channel), 2.5 Gsample/s (all channels) |
| Memory Depth | 200 Msamples (standard), upgradeable to 800 Msamples |
| Vertical Resolution | 8-bit ADC (up to 16-bit with High Definition mode) |
| Display | 10.4-inch capacitive touchscreen, 1024 x 768 resolution |
| Input Impedance | 1 MΩ || 13 pF / 50 Ω |
| Time Base Range | 25 ps/div to 10,000 s/div |
| Waveform Update Rate | Up to 1,000,000 waveforms/second |
| Connectivity & Interfaces | USB, LAN (LXI), DisplayPort, optional GPIB |
Rohde & Schwarz RTO2034 Digital Oscilloscope Options:
- RTO2034 - B1 - Mixed Signal Option, 400 MHz (additional 16 logic channels)
- RTO2034 - B4 - OCXO 10 MHz (precision reference frequency with reference input and output connectors)
- RTO2034 - B10 - GPIB Interface
- RTO2034 - B19 - Additional Solid State Disk
- RTO2034 - B101 - Memory Upgrade, 100 Msample per channel
- RTO2034 - B102 - Memory Upgrade, 200 Msample per channel
- RTO2034 - B104 - Memory Upgrade, 400 Msample per channel
- RTO2034 - B110 - Memory Upgrade, 1 Gsample per channel
- RTO2034 - B234 - Upgrade of RTO2034 to 4 GHz bandwidth
- RTO2034 - K1 - I2C/SPI Serial Decoding
- RTO2034 - K2 - UART/RS-232/RS-422/RS-485 Serial Decoding
- RTO2034 - K3 - CAN/LIN Serial Triggering and Decoding
- RTO2034 - K4 - FlexRay Serial Triggering and Decoding
- RTO2034 - K5 - I2S Serial Triggering and Decoding
- RTO2034 - K6 - MIL-STD-1553 Serial Triggering and Decoding
- RTO2034 - K7 - ARINC 429 Serial Triggering and Decoding
- RTO2034 - K8 - Ethernet Serial Decoding
- RTO2034 - K9 - CAN-FD Serial Triggering and Decoding
- RTO2034 - K10 - SENT Serial Triggering and Decoding
- RTO2034 - K11 - I/Q Software Interface
- RTO2034 - K12 - Jitter Analysis
- RTO2034 - K13 - Clock Data Recovery
- RTO2034 - K17 - High Definition Mode
- RTO2034 - K19 - Zone Trigger
- RTO2034 - K22 - Ethernet Compliance Test
- RTO2034 - K23 - Ethernet 10G Compliance Test
- RTO2034 - K24 - BroadR-Reach Compliance Test
- RTO2034 - K31 - Power Analysis
- RTO2034 - K40 - MIPI RFFE Serial Triggering and Decoding
- RTO2034 - K42 - MIPI D-PHY Serial Triggering and Decoding
- RTO2034 - K50 - Manchester and NRZ Serial Triggering and Decoding
- RTO2034 - K52 - 8b10b Serial Decoding
- RTO2034 - K55 - MDIO Serial Triggering and Decoding
- RTO2034 - K60 - USB 1.0/1.1/2.0/HSIC Serial Triggering and Decoding
- RTO2034 - K65 - SpaceWire Serial Triggering and Decoding
- RTO2034 - K92 - eMMC Compliance Test
| Model | RTO2034 |
|---|
The Rohde & Schwarz RTO2034 Digital Oscilloscope offers 4 channels and 3 GHz bandwidth with a 10 Gsample/s sample rate and up to 2 Gsample memory depth. It features high acquisition rates, up to 16-bit vertical resolution, and ultra-low inherent noise for superior signal fidelity. The intuitive touchscreen, zone trigger in time and frequency domains, and SmartGrid display make it highly versatile for multi-domain signal analysis.
This oscilloscope is ideal for detecting signal faults quickly, analyzing time-frequency-logic interactions, and precise debugging with minimal noise interference across various electronic systems.
Testwall can supply the used Rohde & Schwarz RTO2034 Digital Oscilloscope, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Rohde & Schwarz RTO2034 Digital Oscilloscope.