Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) E4416A

Power Meter
1 Channels
9 kHz to 110 GHz Frequency Range
-70 to +44 dBm Power Range
5 MHz max. Video Bandwidth
212.6 × 88.5 × 348.3 mm Dimensions
Request datasheet
Attribute Value
Channels 1
Frequency Range 9 kHz to 110 GHz
Power Range -70 to +44 dBm
Video Bandwidth 5 MHz max.
Dimensions 212.6 × 88.5 × 348.3 mm
Compatible Sensors E9320 series (peak and average); 8480 series, N8480 series, E441x, E930x (average)
Measurement Speed 20 / 40 / 1000 readings/s (E9320 sensors)
Accuracy ±0.02 dB or ±0.5% absolute (average only mode)
Power Reference 50 MHz, 1 mW (0 dBm) ±0.4%, Type-N female
Time Resolution 20 MSa/s; trigger resolution 50 ns
Measurement Types average, peak, peak-to-average, time-gated
Interfaces GPIB, RS-232/RS-422, trigger in/out, recorder output
Weight 4.0 kg

Compatible power sensors

ModelFrequency RangePower RangeSensor Type
8481A10 MHz to 18 GHz-30 to +20 dBmthermocouple
8481B10 MHz to 18 GHz0 to +44 dBmthermocouple, with 25 W attenuator
8481D10 MHz to 18 GHz-70 to -20 dBmdiode, average
8481H10 MHz to 18 GHz-10 to +35 dBmthermocouple, with 3 W attenuator
8482A100 kHz to 4.2 GHz-30 to +20 dBmthermocouple
8482B100 kHz to 4.2 GHz0 to +44 dBmthermocouple, with 25 W attenuator
8482H100 kHz to 4.2 GHz-10 to +35 dBmthermocouple, with 3 W attenuator
8483A100 kHz to 2 GHz-30 to +20 dBmdiode, average
8485A50 MHz to 26.5 GHz (33 GHz with Opt. 033)-30 to +20 dBmthermocouple
8485D50 MHz to 26.5 GHz (33 GHz with Opt. 033)-70 to -20 dBmdiode, average
8487A50 MHz to 50 GHz-30 to +20 dBmthermocouple
8487D50 MHz to 50 GHz-70 to -20 dBmdiode, average
R8486A26.5 to 40 GHz-30 to +20 dBmthermocouple, waveguide
R8486D26.5 to 40 GHz-70 to -20 dBmdiode, average
Q8486A33 to 50 GHz-30 to +20 dBmthermocouple, waveguide
Q8486D33 to 50 GHz-70 to -20 dBmdiode, average
V8486A50 to 75 GHz-30 to +20 dBm (Opt. H02: -60 to +20 dBm)diode, average, waveguide
W8486A75 to 110 GHz-30 to +20 dBmdiode, average, waveguide
8484A10 MHz to 18 GHz-70 to -20 dBmdiode, average
E8486A60 to 90 GHz (Opt. 201: 54 to 95 GHz)-30 to +20 dBm (Opt. 100), -60 to +20 dBm (Opt. 200/201)diode, average, waveguide
E4412A10 MHz to 18 GHz-70 to +20 dBmdiode, CW
E4413A50 MHz to 26.5 GHz-70 to +20 dBmdiode, CW
E9300A10 MHz to 18 GHz-60 to +20 dBmdiode, average, wide dynamic range
E9300B10 MHz to 18 GHz-30 to +44 dBmdiode, average, wide dynamic range
E9300H10 MHz to 18 GHz-50 to +30 dBmdiode, average, wide dynamic range
E9301A10 MHz to 6 GHz-60 to +20 dBmdiode, average, wide dynamic range
E9301B10 MHz to 6 GHz-30 to +44 dBmdiode, average, wide dynamic range
E9301H10 MHz to 6 GHz-50 to +30 dBmdiode, average, wide dynamic range
E9304A9 kHz to 6 GHz-60 to +20 dBmdiode, average, wide dynamic range
E9321A50 MHz to 6 GHz-65 to +20 dBm (average only mode), -50 to +20 dBm (normal mode)peak and average (diode)
E9322A50 MHz to 6 GHz-60 to +20 dBm (average only mode), -45 to +20 dBm (normal mode)peak and average (diode)
E9323A50 MHz to 6 GHz-60 to +20 dBm (average only mode), -40 to +20 dBm (normal mode)peak and average (diode)
E9325A50 MHz to 18 GHz-65 to +20 dBm (average only mode), -50 to +20 dBm (normal mode)peak and average (diode)
E9326A50 MHz to 18 GHz-60 to +20 dBm (average only mode), -45 to +20 dBm (normal mode)peak and average (diode)
E9327A50 MHz to 18 GHz-60 to +20 dBm (average only mode), -40 to +20 dBm (normal mode)peak and average (diode)
N8481A10 MHz to 18 GHz-35 to +20 dBmthermocouple
N8482A100 kHz to 6 GHz-35 to +20 dBmthermocouple
N8485A10 MHz to 26.5 GHz (33 GHz with Opt. 033)-35 to +20 dBmthermocouple
N8486AR26.5 to 40 GHz-35 to +20 dBmthermocouple, waveguide
N8487A50 MHz to 50 GHz-35 to +20 dBmthermocouple
N8488A10 MHz to 67 GHz (to 70 GHz typ.)-35 to +20 dBmthermocouple
Keysight Technologies E4416A Options:
  • E4416A - 002 - Parallel rear panel sensor input connector(s) and front panel reference calibrator connector
  • E4416A - 003 - Parallel rear panel sensor input connector(s) and rear panel reference calibrator connector
  • E4416A - A6J - ANSI Z540 compliant calibration test data including measurement uncertainties
  • E4416A - 1A7 - ISO17025 compliant calibration test data including measurement uncertainties
  • E4416A - 0B0 - Delete manual set
  • E4416A - 0B3 - English language Service Manual
  • E4416A - 0BK - English language manual set (hardcopy User's Guide and English Programming Guide)
  • E4416A - ABD - German localization (hard copy User's Guide and English Programming Guide)
  • E4416A - ABE - Spanish localization (hard copy User's Guide and English Programming Guide)
  • E4416A - ABF - French localization (hard copy User's Guide and English Programming Guide)
  • E4416A - ABJ - Japanese localization (hard copy User's Guide and English Programming Guide)
  • E4416A - ABZ - Italian localization (hard copy User's Guide and English Programming Guide)
  • E4416A - 004 - Delete power sensor cable
  • E4416A - 908 - Rack mount kit (one instrument)
  • E4416A - 909 - Rack mount kit (two instruments)
Calibration Form Keysight (Agilent) E4416A

Repair Form Keysight (Agilent) E4416A
Maximum file size: 40MB

The Keysight (Agilent) E4416A is a single-channel EPM-P series power meter designed for precise peak, average, and time-gated power measurements, using advanced E9320 sensors. It features a high-speed 20 Msample/s sampling rate for reliable analysis of wide bandwidth signals.

With capabilities such as time-gated and free-run measurements, 8 wireless profiles including GSM, CDMA, and Bluetooth™, and included Analyzer Software, this tool supports complex RF signal environments.

Testwall can supply the used Keysight (Agilent) E4416A, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) E4416A.

Clicky
Copyright © 2025-present Magento, Inc. All rights reserved.